- Overview
- Features
- Patient positioning
-
Maquet Yuno II Mobile Operating Table
A foundation for the future
Growing cost pressures require investments in safe and flexible operating tables that can be universally used in conventional or minimally invasive procedures.
Maquet Yuno II ensures the positioning and access needed to achieve optimum results in open or minimally invasive interventions. The table can be configured for any discipline, increasing your options and maximizing the functionality of your OR. Easy handling ensures that Maquet Yuno II will simplify positioning for even the most complex techniques to help you focus on what’s most important: your patients.
The right choice for minimally invasive techniques
Minimally invasive surgery (MIS) can improve patient outcomes and save costs. Maquet Yuno II supports a variety of positions, bringing the benefits of MIS to patients of various sizes. Radiolucent carbon fiber accessories improve intraoperative diagnostics.
Ready when you are
When trauma patients arrive in your emergency department, there’s no time to lose. Night or day, your OR must be ready. With the flexible Maquet Yuno II Mobile Operating Table, it’s easy to quickly configure the table to meet the needs of the procedure and surgeon, even with limited staff on call.
A cost-effective resource
All hospitals are facing the cost pressure of doing more, doing it better, and doing it safely. Maquet Yuno II is flexible enough to be used as a universal table, extending the functionality of your OR. Compatibility with our existing surgical accessories maximizes your existing investment, reduces your upfront costs, and minimizes the need for training.
Accessories
Traction bar with ball joint including slider
The ball joint is moveable in all directions, supporting DAA procedures and enabling advanced MIS techniques. The slider makes it easy to establish traction, saving time and improving efficiency.
Traction bar including slider
The radiolucent carbon fiber traction bar gives better quality images for improved diagnostics. The slider glides easily over the bar for simple traction setup, saving time and minimizing physical strain.
Screw tension device
The star-shaped handle of the screw tension device can be easily and precisely operated with just one hand. It is equipped with a degree indicator that enables fine tractions to ensure the precise positioning needed for optimal outcomes. It can be attached to the traction devices of Maquet Yuno II and it is also compatible with our existing extension sets.
Sliding clamp
The sliding clamp can be easily moved along the carbon fiber traction bars for precise positioning of accessories where they’re most needed. It attaches to both bars, allowing you to deploy additional accessories during surgery.
Support plate
The support plate supports the non-operative leg during surgery, improving patient comfort and preventing overstretching of the knee. It can be attached to the sliding clamp for flexible positioning anywhere along the traction bars.
Leg plates
Leg plates offer additional support during induction, keeping even the tallest patients safe and comfortable.
Trolley for traction bars
The trolley for traction bars is designed to roll close to the table, minimizing the need to carry the bars. It improves workplace ergonomics and reduces the risk of injury.
Accessory trolley
The accessory trolley can accommodate many accessories in a small space, while still providing fast and ergonomic access. Even when fully loaded, it is very easy to maneuver.
Adapter for counter-traction post for femur in lateral
The adapter allows our existing counter-traction posts to be used on the Maquet Yuno II table to maximize the ROI of your OR table investment and minimize implementation costs.
Traction frame for prone and lateral positions
The traction frame gives surgeons the flexibility to position the patient in prone or lateral positions for pelvic surgery to improve working conditions and deliver the best possible results for the patient.
Elongation adapter for hip scope
The elongation adapter enables the use of the screw tension device for tall patients, eliminating the need for scrub nurses to pull the leg manually. This frees staff resources for more important tasks, and improves patient safety.
Vertical adjustment long and short
The vertical adjustment positions the leg higher for improved site access and patient safety. Two lengths are available to meet specific patient needs and to increase the variety of positioning options.
Frame for sterile drapes
Securely attach the drape to fixed attachments for quick and easy setup.
Tibia adapter
Easily mount our existing tibia and fibula extensions to Maquet Yuno II with the tibia adapter.
Extension plate with three holes
Improve access to pelvis with variable positioning options of the countertraction post. 360° radiolucency provides excellent imaging quality.
Extension plate with one hole
The smart design of the extension plate with one hole improves access to hip. 360° radiolucency improve intraoperative imaging.
Carbon fiber plate for Yuno II
Intraoperative imaging can improve outcomes for patients, giving surgeons clear insights during the procedure. But imaging technologies require specialized infrastructure to support precise visualization. That’s why Getinge has developed a carbon fiber (CF) plate to provide unrestricted radiolucency for pelvic, cardiovascular, orthopedic, and traumatology procedures.
The CF plate has interdisciplinary functionality, expanding the capabilities of your surgical suite. With an X-ray range of up to 45 inches, the C-arm can be positioned to create an imaging window at nearly every angle.
Precise positioning options for minimally invasive procedures with Maquet Yuno II
Direct anterior approach (DAA) to total hip replacement
The direct anterior approach requires a complex course of leg movements. The traction bar with ball joint mimics the smooth multidirectional movement of the hip itself. This Maquet Yuno II bar is easy to operate, flexible to position, and securely locked to prevent overextension and keep the patient safe.
Simplifying DAA to total hip replacement
- Fast and simple traction set-up so you can focus on the patient
- Precise leg rotations to prevent injuries
- Smooth multidirectional movement optimizes access to the surgical site
- Smart design improves workflows and minimizes strain for the surgical team
- Carbon fiber elements support intraoperative imaging
1. Basic set-up
In the basic setup, both legs are parallel. Traction can be set up easily by pulling the slider and rotating the handle of the screw tension device.
2. Lowering the leg
Releasing the handles at the end of the bar smoothly lowers the leg.
3. Rotating the leg
The required outside rotation can easily be set up by pulling and turning the star shaped handle of the screw tension device.
4. Adducting the leg
Manage abduction and adduction of the leg by releasing the handles of the traction bars and moving the bar into the desired position.
Hip scope
In order to gain proper access for hip scope procedures, the femoral head must be pulled out of the acetabulum under maximum traction. Maquet Yuno II is designed to comfortably enable strong traction of up to 80 kg. It offers the flexibility needed to handle a diverse patient population, preventing manual strain on the scrub nurse.
Maximizing traction for hip arthroscopy
- Increase patient safety with improved ventral capsule release
- Improve working conditions with maximum traction of up to 80 kg
- Simplify workflow with slide function and screw tension device
- Increase flexibility to handle a patient population of diverse sizes with elongation adapter
- Flexible set up opportunities on either traction bar
Setting up angles
Maquet Yuno II enables hip scope positioning for even very tall patients using the elongation adapter. Lifting the traction bar allows staff to position the operated leg at an angle that protects the ventral capsule to increase patient safety.
Releasing traction
Traction can be released easily by releasing the slider and moving the screw tension device along the bar.
Adducting the leg
It is easy to move the bar up/down or abduct/adduct by releasing the handles at the end of the bar.
Rotating the leg
External/ internal rotation of the leg can be achieved by turning the star-shaped handle of the screw tension device.
Tibia
Enhanced access and optimal patient positioning are crucial for the outcome of tibia nailing procedures. An angle of 90° or below improves the access for the tibia nailing.
Improving access to tibia
- Enables improved angles for tibia access
- Compatibility with existing extension accessories minimizes implementation costs and maximizes ROI of existing equipment
Enhancing imaging possibilities for shoulder surgery
- Maquet Yuno II contours perfectly to the patient’s body to comfortably accommodate the full range of shoulder and upper arm procedures
- Carbon fiber elements enhance intraoperative imaging to improve outcomes
Universal usage possibilities of Maquet Yuno II for fracture repairs and neurosurgery
Femur
The longest and strongest bone in the body, the femur, requires a tremendous amount of force to set fractures. Ergonomic positioning for the surgeon and accessibility of intraoperative imaging are of equal importance for a successful patient outcome. With Maquet Yuno II, surgical teams can easily position the table in the ideal configuration for both surgeon and patient. The smart design of the carbon fiber traction bars reduces the complexity of femur set ups and improves the surgical workflow.
Improving ergonomics for femur fracture repair
- Highest table settings on the market improve ergonomics for the surgeon
- Carbon fiber bars improve intraoperative imaging
- The smart design of the carbon fiber traction bars reduces the complexity of femur set ups
Improving imaging
Carbon fiber traction bars improve image quality and give optimal access for C-arms.
Simplifying complex set ups
Smart design of the traction device simplifies even complex set-ups for femur procedures.
Improving workflows
The frame for sterile drapes securely attaches the drape to fixed attachments for quick and easy setup.
Increasing opportunities
Maquet Yuno II is compatible with the existing extension set 1433.41 AC/BC to increase your flexibility and the value of your investment.
Pelvis
Traumatic pelvic fractures often cause extensive bleeding and organ injuries that require urgent treatment and clear intraoperative imaging. Maquet Yuno II can reduce the time to treatment, a critical factor in survival rates for traumatic pelvic injuries.
Providing excellent imaging access for pelvic fractures
- Quick set up to reduce the time to treatment
- Flexible prone, supine and lateral positioning to meet surgeons’ preferences
- Carbon fiber devices enhance imaging quality
Neurosurgery
Neurosurgeons require the utmost stability as they work with delicate nerve structures. Maquet Yuno II incorporates several important safety features to prevent accidental table movements.
Ensuring exceptional stability
- Cast iron three-point stand provides excellent stability
- Lock functions eliminate accidental table movements
- Flexibility to set up a variety of neurosurgical positions