Select region
Submit

Intergard Woven Aortic Arch and Hemabridge

Woven Vascular Grafts

  • Collagen-coated polyester graft
  • External velour surface and non-velour inner surface
  • Magnetic Resonance Safe
  • Water permeability: < 5ml/cm²/min[1]

Please refer to the Document Tab for legal mentions of products manufactured by INTERVASCULAR SAS.

Collagen-coated external-velour polyester graft

Intergard Woven Aortic Arch properties

  • Pre-sewn branches facilitate attachment of aortic arch vessels to graft allow reduced surgery time [2],[3],[4]
  • Design which features branches to facilitate the attachment of aortic arch vessels to grafts

Intergard Hemabridge properties

  • Design which features branches to facilitate the attachment of aortic arch vessels to grafts

Related products

Aortic

angled-4-branch (1).png
Diameter Length Reference 
20 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2010080810/1
22 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm   HEWAA2210080810/1
24 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2410080810/1
26 mm x 10 mm x 8 mm x 8 mm x 10 mm  50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2610080810/1
28 mm x 10 mm x 8 mm x 8 mm x 10 mm  50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2810080810/1
30 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3010080810/1
32 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3210080810/1
34 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3410080810/1

 

Intergard Hemabridge 

hemabridge.png
Diameter Length Reference 
20 mm x 10 mm  35 cm x 40 cm  HEW2010BRIDGE
22 mm x 10 mm   35 cm x 40 cm HEW2210BRIDGE
24 mm x 10 mm  35 cm x 40 cm  HEW2410BRIDGE
26 mm x 10 mm 35 cm x 40 cm  HEW2610BRIDGE
28 mm x 10 mm 35 cm x 40 cm  HEW2810BRIDGE
30 mm x 10 mm  35 cm x 40 cm  HEW3010BRIDGE
32 mm x 10 mm  35 cm x 40 cm   HEW3210BRIDGE
34 mm x 10 mm  35 cm x 40 cm  HEW3410BRIDGE
36 mmx10 mm  35 cm x 40 cm  HEW3610BRIDGE
  1. 1. Data on file

  2. 2. Sakamoto, S., et al., Clinical results of aortic arch replacement using a four branched prosthetic graft. J Cardiovasc Surg (Torino), 2003. 44(6): p. 751-5.

  3. 3. Bednarkiewicz, M., et al., Aortic arch replacement using a four-branched aortic arch graft. Eur J Cardiothorac Surg, 2002. 21(1): p. 89-91.

  4. 4. Kazui, T., Total arch replacement with separated graft technique and selective antegrade cerebral perfusion. Ann Cardiothorac Surg, 2013. 2(3): p. 353-7.

  5. 5. Kazui, T., et al. (2001) Use of aortic arch branched graft in the treatment of aortic arch aneurysm or aortic dissection. [Intervascular PN20125/1]

Dear user, You now see International fallback content. Getinge South East Asia does not review or control this content. It is possible that some of the products on Getinge international are not approved in your country. For more specific  information relevant for your region please contact us.