Välj region
Bekräfta

Flow-e Anesthesia Machine

Our extended anesthesia model for a streamlined workflow

Flow-e is our extended and flexible anesthesia machine for a dynamic anesthesia delivery. An extended workstation with a larger worktop, extra storage space, and generous mounting possibilities for auxiliary equipment.

Dynamic Anesthesia Delivery - Every. Breath. Counts. 

Getinge Flow-e anesthesia machine is our extended model for a streamlined workflow in the OR
Flow-e is Getinge's extended anesthesia machine that ensures efficient ventilation performance and personalized care in the OR.
Getinge Flow-e anesthesia machine is our extended model with a larger worktop and more storage space

Extended functionality in the OR

Flow-e delivers personalized anesthesia for a wide range of patients suitable for complex cases as well as general procedures.

  • ICU-grade ventilation performance
  • Safe and easy low-flow anesthesia
  • MAC Brain for informed anesthetic dosing decisions
  • Active hypoxia prevention with O2Guard
  • Lung Recruitment Maneuvers to prevent postoperative complications

Our unique anesthesia technology makes the difference

 

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. With simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1][2][3][4][5][6]

 

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter atelectasis, to improve oxygenation and help prevent postoperative complications. What once was considered complex and time consuming is now seamlessly integrated into your workflow. [11] [12]

User-friendly anesthesia machine in the OR

 

4 drawers

One large and three smaller

Well-designed drawers take care of your space and storage needs. Slots for spare vaporizers and an optional lockable compartment

 

278 cm rails

For flexible mounting

An unmatched length of stepless rails enabling you to add all the monitors and accessories you need.

Ansvarsfriskrivning

Produkterna, tillgängligheten för anestesisystemen i Flow-serien och programversionen kan vänta på regulatoriska godkännanden för marknadsföring i ditt land. Vänligen kontakta din Getinge-representant för mer information. De uttalanden som lämnas av läkare är uteslutande läkarens och speglar inte nödvändigtvis Getinges uppfattning.
Juridisk tillverkare · Maquet Critical Care AB · Röntgenvägen 2 SE–171 54 Solna · Sverige · +46 (0)10 335 73 00

Our unique anesthesia technology makes the difference

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. Automation eliminates the need of continuous manual adjustments: with simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Active hypoxia prevention

Our O2Guard is the world’s only system for active hypoxia prevention. Should the inspired oxygen level drop below 21%, the O2Guard automatically overrules the settings and increases the flow of oxygen. [7]

Mac brain anesthesia flow

MAC Brain

Informed anesthetic dosing

To facilitate decision-making when planning and dosing anasthesia agents, we created MAC Brain. Using mathematical models and data-driven algorithms, MAC Brain visualizes the difference in agent effect in the lungs and the brain - actings as a decision-support framework to help guide anesthetic dosing.[8]

Lung recruitment flow anesthesia

Lung recruitment

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter
atelectasis, to improve oxygenation and help prevent postoperative complications. [9] [10]

Ventilation anesthesia flow

Ventilation performance

Offering ICU-grade ventilation

Innovative Flow Core Technology is designed to promote efficient agent usage, providing the power and precision to ventilate even challenging patients. [11] [12]

User-friendly anesthesia machine in the OR

Developed together with clinicians, the extended Flow-e anesthesia machine is designed to facilitate a great scope for configuration and patient safety. With an intuitive interface and emphasis on ease of use [13], our anesthesia solutions ensure a streamlined workflow and efficiency in the operating room that offers enhanced cost control and resource management.

Our anesthesia workstation

Our anesthesia workstation

1. Open platform

Customized to match your needs

2. USB ports and LED light

USB ports for data transfer and power supply are easily accessible. Three step dimmable LED lights up the workspace.

3. Intuitive control panel

A flexibel touchscreen, with quick access presets, gives you one point of control for all functions. 15%u201D tiltable and rotatable touch screen.

See the video
4. Auxiliary O2 and suction

5. Water trap

Visible and accessible

6. Snap on hooks

For convenient placement of tubes, manual breathing bags, suction tips and other accessories.

7. CO2 absorber

Easy to change

8. Large and flexible workspaces

Practical for your everyday needs

9. Electronic vaporizers in double slots

Precise and cost-efficient

See the video
10. 278 cm multipurpose rails

Extensive and flexible mounting options with 5 multipurpose rails

Watch the video
11. Large drawers

Well-designed drawers take care of your space and storage needs. - Integrated slots for spare vaporizers - Soft close drawer - Lockable compartment (optional)

Watch the video
12. Central 4-wheel brake and cable pushers

Enhances device mobility

13. Smart cable and hose management

Less clutter, easier cleaning and improved mobility

Heltäckande service och support

 

Undvik att avbryta procedurer

Anslut och ta kontroll

Webbportalen Getinge Online ansluter dig till alla Getinge-enheter och ger dig tillgång till värdefulla data som hjälper biomedicinska analytiker och läkare i deras dagliga arbete. Portalen är ett kraftfullt verktyg för att förbättra drifttiden och effektivt använda sjukhusets resurser. 

  • Förbättra drifttiden i operationssalen
  • Minska kostnader och koldioxidavtryck
Man looking straight smiling

Ett enhetligt erbjudande

Getinges heltäckande tjänster maximerar drifttiden och det långsiktiga värdet av din investering. Vi tillhandahåller en serviceplan som innefattar proaktivt underhåll, enkel felsökning och snabb service av våra certifierade lokala representanter – så att din utrustning hela tiden fungerar optimalt.

Anesthesia consumables

Förbrukningsartiklar av hög kvalitet

Getinges sortiment av originalförbrukningsartiklar är särskilt utvecklat för högsta möjliga patientsäkerhet och användarvänlighet. Våra originaltillbehör och förbrukningsartiklar garanterar bästa prestanda och säkerhet för anestesitillförselsystemet inom Flow-serien.

MSync

Anslutningar mellan system

MSync gör det enkelt att ansluta Flow-maskinen till patientmonitorn, HIS och patientdatahanteringssystemet utan behov av ett tredjepartssystem. Patientdata överförs via HL7 (MSync) i realtid för att stödja beslutsfattande.

Visit our Academy – training and education designed to enhance your proficiency

For more information about onsite events or remote trainings, you can also contact your local sales & service representative.

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Moran P, Barr, D, Holmes, C, Saving sevoflurane: Automatic gas control can reduce
    consumption of anesthetic vapor by one-third in pediatric anesthesia.Paediatric
    Anaesthesia. 2019 Apr; 29(4):310-314.

  3. 3. Yusuf Z. Colak & Hüseyin I. Toprak. Feasibility, safety, and economic consequences of using minimal flow anaesthesia by Maquet FLOW‑i equipped with automated gas control. Scientific Reports (2021) 11:20074.

  4. 4. De Medts R, Carette R, De Wolf A, Hendrickx J. Desflurane usage during anesthesia with and without N2O using FLOW-i Automatic Gas Control with three different wash-in speeds. J Clin Monit Comput (2018) 32:763–769.

  5. 5. D. Mostad, P Klepstad, T Follestad & H Pleym, Desflurane consumption with
    automated vapour control systems in two different anaesthesia machines. A randomized controlled study. Acta Anaesthesiol Scandinavica. 2021 Aug;65 (7):895-901.

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z

  7. 7. Hendrickx J, Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-68.

  8. 8. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  9. 9. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  10. 10. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  11. 11. Internal test reports comparing Flow-i with vendor machines

  12. 12. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  13. 13. Internal report NPS Summary Anesthesia 2019