Выберите регион
Отправить

Flow-e Anesthesia Machine

Our extended anesthesia model for a streamlined workflow

Flow-e is our extended and flexible anesthesia machine for a dynamic anesthesia delivery. An extended workstation with a larger worktop, extra storage space, and generous mounting possibilities for auxiliary equipment.

Dynamic Anesthesia Delivery - Every. Breath. Counts. 

Getinge Flow-e anesthesia machine is our extended model for a streamlined workflow in the OR
Flow-e is Getinge's extended anesthesia machine that ensures efficient ventilation performance and personalized care in the OR.
Getinge Flow-e anesthesia machine is our extended model with a larger worktop and more storage space

Extended functionality in the OR

Flow-e delivers personalized anesthesia for a wide range of patients suitable for complex cases as well as general procedures.

  • ICU-grade ventilation performance
  • Safe and easy low-flow anesthesia
  • MAC Brain for informed anesthetic dosing decisions
  • Active hypoxia prevention with O2Guard
  • Lung Recruitment Maneuvers to prevent postoperative complications

Our unique anesthesia technology makes the difference

 

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. With simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1][2][3][4][5][6]

 

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter atelectasis, to improve oxygenation and help prevent postoperative complications. What once was considered complex and time consuming is now seamlessly integrated into your workflow. [11] [12]

User-friendly anesthesia machine in the OR

 

4 drawers

One large and three smaller

Well-designed drawers take care of your space and storage needs. Slots for spare vaporizers and an optional lockable compartment

 

278 cm rails

For flexible mounting

An unmatched length of stepless rails enabling you to add all the monitors and accessories you need.

Заявление об отказе от ответственности

Продукты, доступность анестезиологических систем семейства Flow и версия ПО могут находиться в ожидании разрешения регуляторного органа в вашей стране. Дополнительную информацию можно получить у представителей Getinge. Заявления врача являются исключительно его профессиональным мнением и не обязательно отражают точку зрения компании Getinge.
Официальный производитель · Maquet Critical Care AB · Röntgenvägen 2 SE-171 54 Solna · Швеция · +46 (010) 335-73-00

Our unique anesthesia technology makes the difference

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. Automation eliminates the need of continuous manual adjustments: with simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Active hypoxia prevention

Our O2Guard is the world’s only system for active hypoxia prevention. Should the inspired oxygen level drop below 21%, the O2Guard automatically overrules the settings and increases the flow of oxygen. [7]

Mac brain anesthesia flow

MAC Brain

Informed anesthetic dosing

To facilitate decision-making when planning and dosing anasthesia agents, we created MAC Brain. Using mathematical models and data-driven algorithms, MAC Brain visualizes the difference in agent effect in the lungs and the brain - actings as a decision-support framework to help guide anesthetic dosing.[8]

Lung recruitment flow anesthesia

Lung recruitment

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter
atelectasis, to improve oxygenation and help prevent postoperative complications. [9] [10]

Ventilation anesthesia flow

Ventilation performance

Offering ICU-grade ventilation

Innovative Flow Core Technology is designed to promote efficient agent usage, providing the power and precision to ventilate even challenging patients. [11] [12]

User-friendly anesthesia machine in the OR

Developed together with clinicians, the extended Flow-e anesthesia machine is designed to facilitate a great scope for configuration and patient safety. With an intuitive interface and emphasis on ease of use [13], our anesthesia solutions ensure a streamlined workflow and efficiency in the operating room that offers enhanced cost control and resource management.

Our anesthesia workstation

Our anesthesia workstation

1. Open platform

Customized to match your needs

2. USB ports and LED light

USB ports for data transfer and power supply are easily accessible. Three step dimmable LED lights up the workspace.

3. Intuitive control panel

A flexibel touchscreen, with quick access presets, gives you one point of control for all functions. 15%u201D tiltable and rotatable touch screen.

See the video
4. Auxiliary O2 and suction

5. Water trap

Visible and accessible

6. Snap on hooks

For convenient placement of tubes, manual breathing bags, suction tips and other accessories.

7. CO2 absorber

Easy to change

8. Large and flexible workspaces

Practical for your everyday needs

9. Electronic vaporizers in double slots

Precise and cost-efficient

See the video
10. 278 cm multipurpose rails

Extensive and flexible mounting options with 5 multipurpose rails

Watch the video
11. Large drawers

Well-designed drawers take care of your space and storage needs. - Integrated slots for spare vaporizers - Soft close drawer - Lockable compartment (optional)

Watch the video
12. Central 4-wheel brake and cable pushers

Enhances device mobility

13. Smart cable and hose management

Less clutter, easier cleaning and improved mobility

Комплексное сервисное обслуживание и поддержка

 

Предотвращение отмены процедур

Подключение и полный контроль

Через веб-портал Getinge Online вы можете подключиться к любому устройству Getinge и получить доступ к ценным данным, необходимым биомедикам и врачам в повседневной работе. Этот портал представляет собой эффективный инструмент для увеличения времени бесперебойной работы и эффективного использования ресурсов больницы. 

  • Увеличение времени непрерывной работы в операционной
  • Сокращение затрат и выбросов парниковых газов
Man looking straight smiling

Единое предложение

Услуги Getinge Services позволяют максимально увеличить время безотказной работы оборудования и долгосрочную ценность ваших инвестиций. Мы предоставляем план обслуживания, который включает профилактическое техническое обслуживание, простую в применении услугу поиска и устранения неисправностей, а также оперативное обслуживание сертифицированными представителями на местах, что гарантирует постоянную работу вашего оборудования с максимальной эффективностью.

Anesthesia consumables

Качественные расходные материалы

Ассортимент оригинальных расходных материалов Getinge разработан специально для обеспечения максимально возможной безопасности пациентов и простоты использования. Наши оригинальные принадлежности и расходные материалы гарантируют максимальную эффективность и безопасность анестезиологической системы семейства Flow.

MSync

Возможность связи между системами

MSync позволяет легко подключить аппарат Flow к монитору пациента, больничной информационной системе и системе управления данными пациента без необходимости использования системы стороннего производителя. Данные пациента передаются через HL7 (MSync) в режиме реального времени для поддержки принятия решений.

Visit our Academy – training and education designed to enhance your proficiency

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Moran P, Barr, D, Holmes, C, Saving sevoflurane: Automatic gas control can reduce
    consumption of anesthetic vapor by one-third in pediatric anesthesia.Paediatric
    Anaesthesia. 2019 Apr; 29(4):310-314.

  3. 3. Yusuf Z. Colak & Hüseyin I. Toprak. Feasibility, safety, and economic consequences of using minimal flow anaesthesia by Maquet FLOW‑i equipped with automated gas control. Scientific Reports (2021) 11:20074.

  4. 4. De Medts R, Carette R, De Wolf A, Hendrickx J. Desflurane usage during anesthesia with and without N2O using FLOW-i Automatic Gas Control with three different wash-in speeds. J Clin Monit Comput (2018) 32:763–769.

  5. 5. D. Mostad, P Klepstad, T Follestad & H Pleym, Desflurane consumption with
    automated vapour control systems in two different anaesthesia machines. A randomized controlled study. Acta Anaesthesiol Scandinavica. 2021 Aug;65 (7):895-901.

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z

  7. 7. Hendrickx J, Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-68.

  8. 8. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  9. 9. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  10. 10. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  11. 11. Internal test reports comparing Flow-i with vendor machines

  12. 12. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  13. 13. Internal report NPS Summary Anesthesia 2019