- Overview
- Technical Data and Accessories
-
Getinge 700HC-E Series Steam Sterilizers
Custom cycle naming for up to 23 cycles
Featuring an AVANTI 8.4" touchscreen display making it easier than ever to custom name cycles for fast, accurate identification. The 700HC-E Series offer cycles employing either gravity/downward displacement or dynamic air-removal pressure/vacuum pulsing. Offering up to 23 cycles, in two easy steps for applications including wrapped and unwrapped porous and non-porous hard goods, utensils, gowns or towel packs and liquids in self-venting or unsealed containers.
AAMI ST8 compliant for trays up to 25 lbs each
Validated with programs for both gravity and pre-vacuum cycles at either 132ºC or 135ºC
Exceptional safety and reliability built into all aspects of design and operation
Related products
Model length | 39" (1000mm) | 53" (1350mm) | 61" (1550mm) |
Type | Gravity and vacuum steam | Gravity and vacuum steam | Gravity and vacuum steam |
Chamber width | 26.5" (672mm) | 26.5" (672mm) | 26.5" (672mm) |
Chamber height | 36" (920mm) | 36" (920mm) | 36" (920mm) |
Chamber volume | 21.5 Cu Ft (610L) | 29.3 Cu Ft (829L) | 33.7 Cu Ft (954L) |
Twenty three factory cycles include:
-
One immediate-use cycle for unwrapped goods
-
One vacuum-leak test cycle
-
Ten high-vacuum cycles
-
One Bowie Dick cycle
-
Eight gravity cycles
-
Two liquid cycles
700 Series Load Car and Transfer Carriage
The 700 series load car frame is constructed of tubular stainless steel. The load car is supplied with a fixed bottom shelf, for use as a flat bed, plus (2) adjustable SST shelves. Each adjustable shelf has a pair of side rails and easily accommodates various shapes and sizes and eight adjustable shelving elevations are provided to meet various item heights. The side rails are full length and easily adjusted to hold processed items within the frame of the load car.
The transfer carriage is fabricated of formed stainless steel sections and rectangular stainless steel tubing, with high impact threaded casters. The height is adjustable via the threaded casters. A self-centering latch provides alignment, and securely locks the carriage to the sterilizer for an easy and safe transfer carriage.
Peel Pouch Sterilization Rack
Designed to hold plastic/paper peel pouches in a vertical position during a sterilization cycle. Use inside a tray for easy and safety of load removal. This rack provides spacing to ensure sterilant contact to all surfaces and drainage if moisture is present during a cycle.
Instrument Basket
Modular instrument tray with perforated bottom and solid sides to prevent small instruments from sticking out. Includes carrying handles.
Water Saver Packages
The Getinge MP-129 Water Saver Modernization Package is intended for use on healthcare or scientific mechanical air-removal and gravity displacement Getinge steam sterilizers. Water Consumption can be reduced significantly when the equipment is operated as recommended in the sterilizer operating instructions.